Modeling Electrodes and External Short Circuits in Corrosion Analyses

Edmund Dickinson March 14, 2017
Share this on Facebook Share this on Twitter Share this on Google+ Share this on LinkedIn

In corrosion analysis, we often want to study corroding surfaces whose electrical connectivity is not as simple as a controlled current or voltage. Instead, an electrode surface might be short circuited to another electrode through a direct connection, such as the electrical connection between a monopile and transition piece. Here, we look at how to describe these electrodes and external short circuits using the appropriate boundary conditions in the COMSOL Multiphysics® software.

Simulating Short Circuits and Galvanic Corrosion

Previously, we’ve discussed modeling a short circuit in a lithium-ion battery. In that case, we consider a battery cell short circuited by a nail, where the electrical current path through the nail is drawn directly in the geometry.

Galvanic corrosion is another system where the electrical connectivity between metal surfaces is important. In galvanic corrosion, two metals with different electrochemical reactivities are placed in electrical contact. This provides an electrical current path so that one metal corrodes while a chemical (usually oxygen dissolved in water) is reduced at the more noble metal.

For example, to model galvanic corrosion, we can choose to use a magnesium alloy joined to mild steel. The magnesium corrodes preferentially, as it has a more negative (oxidizing) corrosion potential. After some time, the magnesium electrode material is corroded.

A plot of the electrolyte potential and current density in a galvanic corrosion process.
Electrolyte potential profile (color surface) and current density (arrows). Electrolyte current flows from the corroding magnesium alloy (right) to the mild steel (left).

Because metals have a very high electrical conductivity when compared to the electrolyte, we normally consider the metal to be at a uniform electric potential. If two metals are joined to each other, the whole surface is at a constant potential. This is the characteristic condition of galvanic corrosion — there is no applied voltage between the electrodes. Instead, the electrochemical cell is polarized due to the different electrochemical environments and reactivites of the two metals. This difference in reactivity creates charge double layers that differ in their potential on the different metals.

For convenience, we often use this potential as the system ground, representing the short-circuited metals with a simple boundary condition on the electric potential, φs. In an electrochemical model, we set φs = 0 across the whole connected metal surface using the Electrode Surface boundary condition.

As we can see from the figure above, it’s certainly not the case that the electrolyte potential is uniform across the surface. Instead, the electrolyte potential varies, depending on the local corrosion potential that’s set in the Electrode Reaction boundary condition. It might also depend on electrode kinetics or mass transport. (To understand the relation of these potentials to current distribution, take a look at this blog post on choosing a current distribution interface.)

The image above is taken from the Galvanic Corrosion with Electrode Deformation tutorial. In this model, we define the magnesium and mild steel as being in electrical contact by applying an Electrode Surface boundary condition with the External electric potential set to 0 V.

A screenshot of the settings for the Electrode Surface boundary condition in COMSOL Multiphysics®.
The Electrode Surface boundary condition applies an external electric potential of 0 V to the mild steel surface. An identical condition is used on the magnesium alloy, but it has a different electrochemical reactivity.

Sacrificial Anode Cathodic Protection in Corrosion Analyses

The phenomenon of galvanic corrosion is exploited intentionally in sacrificial anode cathodic protection. To protect a structural component (usually steel) from corroding, it is electrically connected to a sacrificial anode made of a less noble metal. The sacrificial anode then corrodes preferentially. Note that in order for the sacrificial anode to protect the steel effectively, there needs to be a direct electrical connection between the two metals to close the electrical circuit. In effect, the sacrificial anodes are short circuited to the protected surface so that they start to corrode.

When we define sacrificial anodes in a COMSOL Multiphysics model, we can use the same approach as in the idealized galvanic corrosion example above. The electric potential is set uniformly to 0 V on both the sacrificial anode and protected steel surfaces. Below, we see an analysis of a steel platform taken from the Anode Film Resistance Effect on Cathodic Protection tutorial. In this model, we define the steel surface with the same external electric potential condition that’s described in the previous section.

A screenshot showing how to apply an external electric potential to a steel surface for corrosion analyses.
The Electrode Surface boundary condition applies an external electric potential of 0 V to the steel surface. The same condition with a more negative corrosion potential causes the sacrificial anodes to corrode.

Modeling Electrodes and External Short Circuits in COMSOL Multiphysics®

What if the electrical contact between two metal surfaces is not ideal? For example, they might be linked by cables that have an appreciable electrical resistance. Rather than setting the electric potential directly to 0 V, we use the External Short boundary condition, available as of COMSOL Multiphysics version 5.2a. This setting defines the external electric potential on an electrode surface as a uniform floating potential that is connected to ground by a series resistance. The exact value of the voltage versus ground depends on the total current being drawn at the electrode surface, according to Ohm’s law:

\phi_s = I_\mathrm{tot} R

Let’s look at an example. A common task in offshore cathodic protection is the protection of monopiles. These are the steel foundations used to secure offshore structures such as wind turbine towers in a seabed. Typically, a monopile is structurally connected to a transition piece. While the monopile is always below the water surface, the transition piece extends above it.

A schematic of a cathodic protection system for a monopile structure.
A schematic of a typical offshore monopile structure.

To protect all of the structural steel parts from corrosion, we use a jacket of sacrificial anodes. When the anodes have a direct electrical connection only to the transition piece, the monopile stays protected through the electrical contact it makes via structural contact. As this is not electrically ideal, we use a resistance in the electrochemical model to account for the imperfect electrical connection. We can see an example of this in our Monopile with Dissolving Sacrificial Anodes tutorial model.

A screen capture of the Settings window for the Electrode Surface boundary condition when modeling an uncoated steel surface.
The Electrode Surface boundary condition applies an external short to ground for a monopile’s uncoated steel surface.

The External Short boundary condition links the steel surface to ground (0 V), the electric potential of the transition piece and sacrificial anodes. Between ground and the monopile, we apply a resistance R_Tp with a value of 0.01 Ω. This represents the resistance of the electrical contact between the monopile and transition piece.

While this isn’t a large resistance, including it is very important in this case. The total current drain on the sacrificial anodes that protect the steel surface may be tens of A, so the corresponding loss to resistance can be more than 100 mV. Since the electrochemical properties of a steel surface change from being well protected to poorly protected over a potential range of 100 mV or less, these magnitudes are comparable.

The figure below shows the external electric potential on the different parts of the surface.

An image showing simulation results for external electric potential on a transition piece and monopile.
The external electric potential on a transition piece (top) and monopile (bottom) surrounded by a jacket of sacrificial anodes.

Note that the electric potential is uniform on both surfaces, as they are highly conductive metals. Still, there is a potential difference of more than 140 mV between the monopile and transition piece because of the resistance included in the External Short boundary condition. This means that the steel surface is generally less well protected, which is also shown in the following plot of the electrode surface potential.

A graphic showing results for the electrode surface potential in a transition piece and monopile.
The electrode surface potential in a transition piece (top) and monopile (bottom) surrounded by a jacket of sacrificial anodes.

The blue color indicates negative (cathodic) potential, so the transition piece is relatively well protected. In comparison, the monopile surface is poorly protected and might be a corrosion risk.

The analysis with the External Short boundary condition ensures that the model correctly considers the contribution of resistance between the two structural parts. These results demonstrate that we need to be very careful when designing the protective jacket. If the cathodic protection system is poorly designed, connecting sacrificial anodes only to the transition piece might not provide adequate protection to the monopile.

Learn More About Studying Corrosion with COMSOL Multiphysics®


Categories

Loading Comments...

Categories


Tags